Main Board and Earthing
The main board is examined for condition, labelling and protective devices, and the earthing and bonding arrangements are checked to confirm they are present, connected and suited to the way the building is used.
STEPHEN BROWNELECTRICAL Electrical Testing, Inspection & Certification
An EICR is a written report on the state of an electrical installation that is already in use. Stephen Brown Electrical inspects and tests the wiring, then records what was found in a report you can read and act on.
An Electrical Installation Condition Report, usually shortened to EICR, looks at wiring that has already been in service for some time. Rather than certifying new work, it asks how the existing installation is holding up: whether cables, accessories, protective devices and earthing are in a sound state, and whether anything has been altered, overloaded or left to deteriorate. The result is a written record with coded observations, so the most pressing items stand out from the minor ones.
People ask for an EICR for different reasons. A landlord may want the installation reviewed between tenancies, a buyer may want to know what sits behind the walls of a house before completing, and a business owner may be asked by a lender or insurer for a current report. Stephen Brown Electrical carries out the inspection and testing, explains the observations in plain language and, if remedial work turns up, can quote for it separately from the report itself.
The main board is examined for condition, labelling and protective devices, and the earthing and bonding arrangements are checked to confirm they are present, connected and suited to the way the building is used.
Each circuit is tested for continuity, insulation resistance and the response of its protective device, with readings written against the circuit they belong to so the schedule can be followed again later.
A sample of accessories, light fittings and visible cable runs is inspected for cracks, scorching, loose terminals and signs of overheating, within whatever access the property allows on the day of the visit.
Anything needing attention is recorded as an observation with a classification, so you can see which items are urgent, which call for further investigation and which are noted only for your information.
The report states what was inspected and what could not be reached, such as sealed ceilings or locked rooms, so that nobody reads it as covering more than the scope agreed beforehand.
Contact us with the property's location, what type of building it is and the reason the report is wanted. We ask about the age of the wiring, the number of circuits and any known faults before a visit is agreed.
We confirm which parts of the installation will be covered, roughly how long the visit will need and whether the power has to be switched off at any point, so you can plan around it.
We carry out the visual inspection and the testing on site, working through the board and each circuit in turn, and note any limitations as we meet them rather than guessing about them afterwards.
The written report follows, with each observation explained. If remedial electrical work is needed we can discuss it and quote for it separately, and the decision to go ahead stays with you.
Stephen Brown Electrical is based in Markethill and arranges EICR visits across County Armagh, including Newry, Banbridge, Portadown, Armagh, Lurgan, Craigavon, Dungannon, Lisburn, Belfast and nearby towns, generally within about 40 miles of base. Below you will find town pages with notes for each district; pick the nearest to your property.
The report itself recommends a date for the next inspection, based on the condition found and the type of property. For rented homes or business premises, requirements differ, so ask the body that regulates you or whoever insures the building.
Parts of the installation have to be isolated while testing is carried out, usually one circuit at a time. We tell you beforehand which areas will be affected so computers, freezers and other sensitive equipment can be planned around.
It means the report found at least one condition that needs action, such as a dangerous or potentially dangerous defect. It does not mean the whole installation must be replaced. We explain each item and what could put it right.
Someone should be present to give access, or to arrange it with a key holder. A landlord can agree a time with the tenant. Locked rooms, outbuildings and sealed areas that cannot be reached are recorded in the report as limitations.
No. An EICR reports on wiring that already exists, whereas a certificate accompanies new or altered electrical work. If you are unsure which applies, describe the job to us and we will say which document fits.
Request a quote
If you need the condition of your wiring recorded, tell us where the property is and why you want the report. We will get back to you to talk through the inspection and agree what the report should cover.